    • ACE Glycan bioanalytical Columns Avantor? ACE? Glycan is a high performance stationary phase designed for the analysis of 2-aminobenzamide labelled glycans by hydrophilic interaction liquid chromatography (HILIC).
    詳情

    Avantor® ACE® Glycan UHPLC and HPLC bioanalytical columns

    Analytical HPLC/UHPLC columns, Avantor® ACE® Excel Glycan

    Avantor® ACE® Glycan is a high performance stationary phase designed for the analysis of 2-aminobenzamide labelled glycans by hydrophilic interaction liquid chromatography (HILIC). These ultra-inert, high efficiency columns provide excellent column lifetime and reproducibility with buffers and mobile phases typically utilised for glycan analysis. Two particle sizes are available to enable both high resolution and rapid separations on HPLC and UHPLC instrumentation.

    • High efficiency 1,7 and 3 μm particle sizes for high resolution glycan separations
    • Ultra-inert, base deactivated silica for exceptional reproducibility and peak shape
    • Excellent column lifetime under glycan testing conditions

    Avantor® ACE® Glycan UHPLC and HPLC bioanalytical columns offer excellent efficiency and peak shape for the analysis of glycosylation patterns of biopharmaceutical compounds such as monoclonal antibodies, glycopeptides, and glycoproteins.

      • Proprietary HILIC stationary phase designed for the analysis of enzyme-released, fluorophore-labeled glycans (e.g., 2-AB)
      • Ultra-inert silica provides excellent peak shape and high efficiency for both 1.7 and 3.0 μm particle size columns
      • Highly reproducible manufacturing process ensures batch-to-batch and column-to-column reproducibility
      • Excellent column stability under typical glycan analysis conditions (50-60 °C)

      To extend column lifetime, ACE UHPLC guard cartridges (EXL-1P16-GD2U / EXL-1P16-GD4U) are recommended. For the guard system, a guard cartridge holder (H0011) is also required.

       

      Conditions:

      Column: ACE Excel 3 Glycan
      Dimensions: 150 x 2.1 mm
      Mobile Phases: A: 100 mM Ammonium formate in H2O (pH 4.5)
      B: MeCN
      Gradient: Time (mins) %B
      0 75
      24.0 60
      24.3 40
      24.6 40
      24.9 75
      45.0 75
      Flow Rate: 0.5 mL/min
      Injection: 1.5 μL
      Temperature: 55 °C
      Detection: FLD, λex = 260 nm, λem = 430 nm
      Instrument: VWR Chromaster with FLD
      Dwell Volume: 1950 μL

     

    全國服務熱線:020-22826668 | E-mail:gz@gzflm.com
    公司地址:廣東省廣州市天河區天河北路179號尚層國際大廈13層(510620)
    Guangzhou FLM Scientific Instrument Co.Ltd
    Floor 13, No.179 of North TianHe Road, GuangZhou, 510620, China
    CopyRight © 2002-2022 廣州菲羅門科學儀器有限公司 版權所有 粵ICP備05059471號
    免責聲明 | 聯系我們 |
    信用中國  
    掃一掃,添加菲羅門公眾號
    日本高清视频色WWW色
  • <legend id="gi4u4"></legend>
  • <table id="gi4u4"></table>